Loading...
Signaling Items

FAIL SAFE FLASHER (FSF) RELAY

SPECIFICATION NO. : RDSO/SPN/173/2002

RDSO APPROVED. : YES

DESCRIPTION :

Fail Safe Flasher is designed to work at 24V input with variation +30% to -10% ,giving flashing output of 24V DC ±20% at 3A with 50 ± 2 flashes per minute. Micro-controller is used to make the design of the flasher as fail safe so that no steady output is delivered in case of any failure.

 

TECHNICAL SHEET :

The electronic flasher device shall operate satisfactorily either from primary or secondary cells or unsmooth full-wave rectifier supply (true RMS) from single phase,50 Hz sinusoidal AC supply. The rated current, voltage and ambient temperature shall be as follows:-

  • Input voltage : 24V, +30%, -10%
  • Output voltage : 24V±20%
  • Output Current : 3Amps.
  • Flash rate : 50±2 flashes per minutes.
  • Duty cycle : 'ON' time for the flashing output shall be 44% to 46% of the duty cycle.
  • Operating temperature : -10°C to 70°C & 95% RH

The design of the circuit is of fail safe nature so that no steady output is delivered in case of failure or open circuit/short circuit or ageing of any component or any momentary switching OFF/ON of the power supply or external surges due to picking up and dropping of relays connected across the supply to the flasher device.

Enquiry Now

Quality Control

We are an ISO 9001:2015 certified company. Our products are based on Railway/RDSO/IRS specification and are quality assured after extensive internal as well as third party inspection. We have appointed a team of quality analysts to keep a strict vigil on the quality of the products being manufactured right from raw materials to the finished production stage.